Gallery

132/11KV,25MVAPower Transformer with new windings at FACOR

132/11KV,25MVAPower Transformer with new windings at FACOR

132/11KV, 12.5MVA Power Transformer with new windings at Hindustan Ship yard

132/11KV, 12.5MVA Power Transformer with new windings at Hindustan Ship yard

NGEF Furnace Transformer 16MVA HV & LV WINDINGS Assembly

NGEF Furnace Transformer 16MVA HV & LV WINDINGS Assembly

NGEF Furnace Transformer 16MVA Final Assembly with OLTCs

NGEF Furnace Transformer 16MVA Final Assembly with OLTCs

NGEF 21MVA FURNACE TRANFORMER HV WINDING REPLACMENT JOB AT M/s.USHA MARTIN,JAMSHEDPUR

NGEF 21MVA FURNACE TRANFORMER HV WINDING REPLACMENT JOB AT M/s.USHA MARTIN,JAMSHEDPUR

NGEF 21MVA FURNACE TRANFORMER HV WINDING REPLACMENT JOB AT M/s.USHA MARTIN,JAMSHEDPUR

NGEF 21MVA FURNACE TRANFORMER HV WINDING REPLACMENT JOB AT M/s.USHA MARTIN,JAMSHEDPUR

250MVA, 15.75/220KV Generator Transformer HV Winding Repair at M/s.KPCL, RTPS

250MVA, 15.75/220KV Generator Transformer HV Winding Repair at M/s.KPCL, RTPS

MR Tap Changer Servicing

MR Tap Changer Servicing.

NGEF Diverter Switch ServicingNGEF Diverter Switch Servicing.

Energy Auditing

Energy Auditing

Thermography

Thermography

Truck Mounted Tranformer Oil Filter Machine

Truck Mounted Tranformer Oil Filter Machine

LT POWER CAPACITORS

Oil Testing
Type                : MPP & APP Dielectric
Construction    : Box & Cylindrical version
Rating              : 415/440 V, 50 Hz, 3 Phase
Capacity          : 1Kvar to 25Kvar single units
Features          : Low watt loss, Explosion proof.

HT POWER CAPACITORS

Oil Testing
Type                : APP Dielectric
Construction    : Box version
Rating              : From 2.4KV to 20.7KV in 1 / 3 Phase
Capacity          : Max output 750KVAR (Single Phase)
Features          : Ultra Low watt loss, Indoor & Outdoor

SERIES REACTOR FOR HARMONICS PROTECTION

Oil Testing
Type               : Detuned, Copper Wound, Iron Core Dry
Construction   : Open execution
Rating             : 440V, 550V, 690V
Capacity         : Output upto 100KVAR
Filter Factor    : 5.67%, 7%, 14%
Features         : Low watt loss, Limiting Inrush Current

AUTOMATIC POWER FACTOR CORRECTION RELAY

Oil Testing
Type              : Microprocessor based
Stages           : 4,6,12,16
Rating            : 230V Auxiliary supply
Features        : Program entry for targeted Power Factor,
                         Automatic calculation of C/k value.

AUTOMATIC POWER FACTOR CORRECTION PANEL

Oil Testing
Type              : Modular, Wall mounted & Foot Mounted
Stages           : 4,6,12,16
Rating            : Min 25KVAR to 300KVAR Single panel
Features        : Incomer MCCB, Capacitor Duty Contactors

ARC FURNACE SECONDARY AMMETER

Oil Testing
Size
:
96mm x96mmx100mm Depth (Cut-out 92mm x 92mm)
Digits
:
4-Digit 14.2mm LED Bright Red.
Range
:
Auto range from 0 to 99.99 Kilo Amps
Input
:
PT Secondary Voltage : 110V from Transformer HV side
CT Secondary Current
:
1A or 5A from Transformer HV
Voltage
:
0-300V from Transformer LV side.
Accuracy
:
1.0%
Display
:
Programmable as per CT and PT ratio
Input
:
PT Secondary Voltage : 110V from Transformer HV
sideProgrammable as per CT and PT ratio
Transformer Efficiency Programmable
Optional
:
Communication Port RS-485